• Underground Mine Use Electric Protection and Control Device
  • Underground Mine Use Electric Protection and Control Device
  • Underground Mine Use Electric Protection and Control Device
  • Underground Mine Use Electric Protection and Control Device

Underground Mine Use Electric Protection and Control Device

Task: Belt Conveyor Protection
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: CCC, ISO: 9001, CE
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
KHP144-K
Condition
New
Customized
Customized
Material
Cast Iron
Warranty
1 Year
Model Number
Khp144-K
Transport Package
Wooden Box
Specification
Customized
Trademark
Wantai
Origin
Huainan, Anhui, China
Production Capacity
1000opieces/Year

Product Description

Electric control device for mine belt conveyor protection

1. Purpose

 

Underground Mine Use Electric Protection and Control Device
The electric control device for mine belt conveyor protection (hereinafter referred to as the electric control device) is mainly equipped with explosion-proof and intrinsic safety control console, explosion-proof and intrinsically safe PLC control box and various protection sensors, which are suitable for the environment with gas and coal dust explosion in coal mine. It is used for electrical control, monitoring and comprehensive protection of belt conveyor and other equipment in coal mine. It can also be used for the control device of electrical equipment in the harsh environment of metallurgy, chemical industry, building materials, electric power, transportation, grain and other industries.

 

2.Characteristics
1.It has the functions of language warning and language accident alarm. The language alarm can not only report the nature of the fault, but also the number of the belt conveyor;
2.It has the same functions as similar products, such as remote control, local control, centralized control, etc;
3.It has the function of speed measurement and temperature measurement, and can directly display the temperature value and speed value;
4.It has field programmable function;
5.It has the function of input / output point expansion;


3.Main technical parameters
Rated input voltage AC127v
Intrinsically safe output voltage U1:24VDC U2:12VDC
Intrinsic safety output current  I1:0.5A, I2:1.3A
The highest open circuit voltage U1: DC 24.5v U2: 12.5V
The maximum intrinsic safety output current is I1: 510ma, I2: 1300ma
Output contact capacity of relay  AC250V / 5A

Basic configuration
1.Switch input: 32 channels, no potential contact;
2.Frequency input: 4 channels, 200-1000hz;
3.Digital input: 2 channels, 0-1000hz;
4.Code input: 1 channel;
5.Switch output: 32 channels, no potential contact;
Display
1.Dot matrix display: 128X64 dot LCD display;
Data transmission
1.Transmission mode: asynchronous mode, conforming to RS-485 standard;
2.Transmission rate: 600bps, 1200BPS, 2400bps;
3.Verification mode: 16 bit CRC cyclic redundancy code verification;
4.Transmission distance: not less than 10km.


Underground Mine Use Electric Protection and Control Device
Underground Mine Use Electric Protection and Control Device
Underground Mine Use Electric Protection and Control Device

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
371
Year of Establishment
2009-08-12