Mining Use Intrinsically Safe Tension Sensor

IP Grade: IP54
Output Signal: Digital Signal
Explosion-Proof Type: Mine Intrinsically Safe
Transport Package: Wooden Box
Specification: 1.5mv/v
Trademark: Wantai
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GAD5
Origin
Huainan, Anhui, China
Production Capacity
10000pieces/Year

Product Description

1.Product use
GAD5 (B) mine intrinsically safe tension sensor is used in underground coal mine, open-pit coal mine, coal preparation plant and other workplaces. It is used to detect the tension protection signal of belt conveyor comprehensive protection device.

2.Functional features
2.1. The structure of tension sensor is simple and easy to install, use and carry;
2.2. It has good sealing and moisture-proof performance;
2.3. It has high anti vibration and impact stability;
2.4. The structure design ensures that the transmission error is small and the measurement is reliable, and has good static and dynamic characteristics;
2.5. It can be used for remote static and dynamic measurement.


3.Main performance
3.1 Output sensitivity: 1.5mv/v
3.2 Nonlinear error: 0.1-0.3% R.O
3.3 Lag error: 0.1-0.3% R.O
3.4 Repeatability error: 0.1% R.O
3.5 Bridge impedance: 350 ohm
3.6 Overload capacity: 20% R.O
3.7 Insulation impedance: 200 megohm
3.8 Excitation voltage: DC12V


4. Technical parameters
4.1. Normal working conditions
4.2. The ambient temperature is - 5 ºC to + 40 ºC;
4.3. The altitude shall not exceed 2000m (86kpa-110kpa);
4.4. The relative humidity of ambient air is not more than 98% (25 ºC);
4.5. In mines containing explosive mixtures of methane;
4.6. Where there is no significant shaking and impact vibration;
4.7. In the environment without gas or steam damaging the insulation, the place that can prevent water dripping.
4.8. Intrinsic safety parameters: UI: dc12.5v, II: 10mA, Li: 0.1mh, CI: 0.1 μ F;
4.9. Input signal: 4 ~ 20mvdc, output signal: 2 ~ 5VDC, error: ± 8%.
Mining Use Intrinsically Safe Tension Sensor
Mining Use Intrinsically Safe Tension Sensor
Mining Use Intrinsically Safe Tension Sensor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
371
Year of Establishment
2009-08-12