Draw-out Type Indoor Vacuum Circuit Breaker (VCB)

Product Details
Customization: Available
Type: Power
Structure: Protection
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
371
Year of Establishment
2009-08-12
  • Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
  • Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
  • Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
  • Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
  • Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
  • Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
Find Similar Products

Basic Info.

Model NO.
VS1
Operation Voltage
High Voltage
Size
1 Uint
Application Range
High-rise Buildings
Shell Material
Aluminum Alloy
Shell Protection Grade
IP55
Brand
Wantai
Transport Package
Wooden Case
Trademark
Wantai
Origin
China
Production Capacity
10000 Sets Per Month

Product Description

Draw-out Type Indoor Vacuum Circuit Breaker (VCB)

Productin introduction


VS1 type (ZN63)-12 indoor vaccum braker is a indoor voltage switch equipment,aplicable to 12KV rated voltage ,3-phase power system frequency 50HZ,used as protection and control electric equipment, as a result of the vaccum arc extinguishing performance is good,anti-fouling ability strong, almost maintenance-free special superiority,espectially suitable for high curent load frequent operation.
Vaccum circuit breaker breaker on outdoor high voltage column is a new type of outdoor high voltage switch equipmetn with rated voltage of 12KV,which is mainly used in distribution system of city network and rural network as load current overload current and short circuit current.The external insulation is made of silicone rubber material ,which has reliable insulation and strong anti-pollution ability.

 
Rated voltage 12kV
Rated frequency 50Hz
Rated Lightning Shock Test Voltage/Fracture 75/85kV( Peak value)
Power Frequency Tolerance Voltage/Fracture Rated 1 Min 42/48kV ( Effective value)
Rated operation sequence 0-t-C0-t1-C0
Circuit Breaker Model Rated current Rated interruption current KA Rated short circuit closing current(peak) KA Rated Short Circuit Duration S Breaking times
ZN63-12/... 630
1250
20/25 50/63 4 100
  1250
1600
2000
2500
31.5 80 4 50




Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
Draw-out Type Indoor Vacuum Circuit Breaker (VCB)
Draw-out Type Indoor Vacuum Circuit Breaker (VCB)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier