Tension Sensor for Coal Mine

Product Details
Customization: Available
IP Grade: IP54
Output Signal: Digital Signal
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
371
Year of Establishment
2009-08-12
  • Tension Sensor for Coal Mine
  • Tension Sensor for Coal Mine
  • Tension Sensor for Coal Mine
  • Tension Sensor for Coal Mine
  • Tension Sensor for Coal Mine
  • Tension Sensor for Coal Mine
Find Similar Products

Basic Info.

Model NO.
GAD5
Explosion-Proof Type
Mine Intrinsically Safe
Transport Package
Wooden Box
Trademark
Wantai
Origin
Huainan, Anhui, China
Production Capacity
10000pieces/Year

Product Description

Coal Mining Use Tension Sensor

1.Product use

GAD5 (B) mine intrinsically safe tension sensor is used in underground coal mine, open-pit coal mine, coal preparation plant and other workplaces. It is used to detect the tension protection signal of belt conveyor comprehensive protection device.

2.Functional features
2.1. The structure of tension sensor is simple and easy to install, use and carry;
2.2. It has good sealing and moisture-proof performance;
2.3. It has high anti vibration and impact stability;
2.4. The structure design ensures that the transmission error is small and the measurement is reliable, and has good static and dynamic characteristics;
2.5. It can be used for remote static and dynamic measurement.


Tension Sensor for Coal Mine
3.Main performance
3.1 Output sensitivity: 1.5mv/v
3.2 Nonlinear error: 0.1-0.3% R.O
3.3 Lag error: 0.1-0.3% R.O
3.4 Repeatability error: 0.1% R.O
3.5 Bridge impedance: 350 ohm
3.6 Overload capacity: 20% R.O
3.7 Insulation impedance: 200 megohm
3.8 Excitation voltage: DC12V


4. Technical parameters
4.1. Normal working conditions
4.2. The ambient temperature is - 5 ºC to + 40 ºC;
4.3. The altitude shall not exceed 2000m (86kpa-110kpa);
4.4. The relative humidity of ambient air is not more than 98% (25 ºC);
4.5. In mines containing explosive mixtures of methane;
4.6. Where there is no significant shaking and impact vibration;
4.7. In the environment without gas or steam damaging the insulation, the place that can prevent water dripping.
4.8. Intrinsic safety parameters: UI: dc12.5v, II: 10mA, Li: 0.1mh, CI: 0.1 μ F;
4.9. Input signal: 4 ~ 20mvdc, output signal: 2 ~ 5VDC, error: ± 8%.
Tension Sensor for Coal Mine
Tension Sensor for Coal Mine
Tension Sensor for Coal Mine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier