Customization: | Available |
---|---|
Task: | Belt Conveyor Protection |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
It is suitable for the dangerous environment of gas and coal dust explosion. Used for electrical control, monitoring and comprehensive protection of belt conveyor and other equipments in coal mine. Equipped with smoke sensors, temperature sensors, speed sensors, coal level sensors, deviation sensors, tear sensors, wire switches, sprinklers and other products produced by the company. It can realize low speed skidding, strip tearing, coal piling, deviation, smoke, ultra-mild emergency stop, tensioning stop and other protection. And can realize the temperature and smoke protection at the same time to stop the temperature (smoke) automatic sprinkler cooling.
1. Limit input voltage: AC127V or 36V, voltage fluctuation allowed: 75-110% Ue
2. Maximum open circuit output voltage of the safety: DC12V± 0.5v
3. Maximum short circuit current output of this ampere: DC40mA; Overcurrent protection setting value: 1.3a.
4. Internal permissible distributed capacitance of internal output: 0.1uF/Km
5. External permissible distributed inductance of intrinsically safe output: 0.1mhKm
6. Relay output contact capacity: AC250V/5A
7. External dimension of this device: 320mm×120mm×330mm, weight less than 15kg.