Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter

  • Audited Supplier
  • 7 yrs

Contact Supplier

Product Highlights

  • Explosion-Proof Design: Suitable for mines with explosive gas and coal dust, ensuring safety in hazardous environments.
  • Siemens PLC Control: Core control unit enables stable performance, centralized networking, and Profibus-DP support.
  • Flexible Parameter Setting: Adjustable starting current and torque curves optimize performance for different load conditions.
  • Intrinsically Safe Circuit: Pilot circuit design prevents spontaneous starting accidents caused by short circuits or grounding.
  • Advanced HMI Interface: 7-inch embedded display provides real-time monitoring of voltage, current, and fault status.
  • Drawer Plug-in Structure: Modular design ensures good interchangeability, consistency, and easy maintenance.
  • Dual Protection System: Combines soft starting and direct starting modes for reliable motor operation.
  • OEM/ODM Services: Customization services available for branding and specific technical requirements.

Product Images of Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter

Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter pictures & photos
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter pictures & photos
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter pictures & photos
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter pictures & photos
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter pictures & photos
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter pictures & photos
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
    Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
    Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
    Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
    Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
    Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
  • Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
    Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter

Find Similar Products

Product Description

Coal Mining AC Vacuum Explosion-Proof Soft Starter


Main application

Mining explosion-proof and intrinsically safe low voltage AC soft starter (hereinafter referred to as starter) is suitable for mine containing explosive dangerous gas and coal dust. in AC 50Hz, rated voltage AC1140(660V) power supply system, four three-phase squirrel cage motors with current below 400A can be started in many forms (such as current limiting, voltage slope and power torque slope). The device PLC is the control core, and the 7-inch Chinese embedded computer is used as the human-computer interaction interface. Support Profibus-DP, industrial Ethernet communication, can achieve centralized control with the ground control center network.

Technical characteristics

1. The soft starting driver adopts WTR-200 controller, and the soft starting performance is stable and reliable, and has the double protection of soft starting and straight up.
2. The starting parameters can be set flexibly according to different loads, and the optimal current curve and torque control characteristics can be obtained.
3. he starting current can be adjusted according to the load, the starting loss is reduced, the optimum torque is generated at the minimum current.
4. The pilot circuit of the equipment is an intrinsically safe circuit, which can effectively prevent the occurrence of spontaneous starting accident caused by short circuit or grounding of the control line.
5. 
Siemens PLC is used as the control core, which can easily realize the centralized control of networking and support Profibus-DP, industrial Ethernet communication.
6. 
The embedded human-computer interaction interface can display the operating conditions of each unit, motor current, voltage real-time display and fault status display, and has the functions of fault record query, current, voltage curve query and so on.
7. Each drive circuit has an independent monitoring and protection unit, which is not affected by each other, and only transmits data and instructions to each other through the formation of the field bus ring network with the superior plc core unit. The utility model has the advantages of high degree of automation, convenient and intuitive man-machine conversation, stable performance, sensitive protection, reliable action and so on.
8. Each unit of the equipment adopts drawer plug-in type, which has good interchangeability and consistency.
9. Keyboard operation, convenient and beautiful.

                                       
Main technical parameters
1. Rated operational voltage:1140V ,660V
2. Rated operational current:800A
3. Intrinsically safe parameter: U10:AC22V/DC15V;I10:AC123mA/DC45mA;
4. Maximum power of motor controlled by each unit at rated voltage of 1140V:590kW;
5. Soft start time:1~180s;
6. Operation frequency:At the maximum condition,12 times/Hour;
7. Cooling-down method:Air convective cooling;
8. Control mode:Proximity control, security remote control, network control


More Products

 
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter



Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter
Coal Mine AC Vacuum Qjr Explosion-Proof Soft Starter


                                         
Contact us

                              

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI209836". Items marked "verified" are certified.

Watch Video
Watch Video
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.
Huainan Wantai Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Wantai Industrial Park, High-tech Zone, Huainan City, Anhui Province
verified Plant Area
41708 square meters
verified Number of Employees
371
verified Registered Capital
57,298,007 RMB
verified Terms of Payment
LC, T/T, PayPal, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Shanghai Port

Our Production Capability & Technical Expertise

verified Main Products
Mine Explosion Proof Equipment, Mine Automation System, Switchgear, Frequency Converter, Microseismic Monitoring System
verified Production Machines
Planer Type Milling Machine, Horizontal Lathe, Machining Center, Radial Drilling Machine, Plate Shearing Machine, Bending Machine, Hydraulic Machine, CNC Machine, Vertical Lathe, Sawing Machine, Punching Machine, Plasma Flame Cutting Machine
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
57 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2009-08-12
Export Year
2009-09-02
verified Main Markets
Southeast Asia/ Mideast, Asia
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE, CCC, Others

FAQ

What is the rated voltage for this starter?
The rated operational voltage is 1140V or 660V AC.
What is the maximum motor current supported?
It supports three-phase squirrel cage motors with a current below 400A per unit, with a rated operational current of 800A.
Can the starting parameters be adjusted?
Yes, starting parameters such as current and torque can be flexibly set according to different loads.
What communication protocols are supported?
The device supports Profibus-DP and industrial Ethernet for centralized control with the ground network.
How is the device cooled?
It uses air convective cooling as the cooling-down method.
What is the maximum operation frequency?
The operation frequency is up to 12 times per hour under maximum conditions.
Is OEM or ODM service available?
Yes, both OEM and ODM services are available for this product.
What is the lead time for production?
The average lead time is one month for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now